Fire Doors

Accessible, with diverse functions and an elegant design.

With a full range of world-leading door closers we have a fire-door solution for every need, so that you can ensure your buildings and its occupants are safe. Our team of experts can work with you to design a solution that will suit all of your compliance, access and safety requirements.

Contact Us

Technical

Fire protections doors in any building can be used for barrier-free access with the various hold-open systems that we have to offer. They will keep the door open and, in an emergency, they will close the doors automatically and safely. We are able to offer complete hold open systems from a single source for preventative fire-protection

Fitting

The GEZE range of hold-open systems are compact and consist of one overhead closer and a guide rail system. All power supplies, smoke switch control units and electromechanical hold-open systems are all conveniently integrated into the guide rails – ensuring a neat installation without any bulky parts, that looks aesthetically pleasing.

Safety

Hold-open systems, safely hold the door open and will remain in the open position, but will reliably and safely close in the event of a fire-alarm, and can prevent the spread of fire and smoke in emergencies.

For single leaf doors
TS 1500 G TS 3000 V TS 5000 ECline TS 5000 L ECline TS 5000 TS 5000 L TS 5000 E TS 5000 L-E TS 5000 R TS 5000 L-R TS 5000 EFS 3-6 TS 5000 RFS 3-6
Approvalforfireandsmokeprotectiondoors1
Barrier-free in accordance with DIN 18040 EN1 750 EN4 1100 EN5 1250 EN5 1250 EN4 1100 EN4 1100 FSA2 FSA2 FSA2 FSA2 FSA FL2 FSA FL2
Closing force acc. to EN 1154 1 1-4 3-5 3-5 2-6 2-6 2-6 2-6 2-6 2-6 3-6 3-6
Door leaf width (max.) in mm 750 1100 1250 1250 1400 1400 1400 1400 1400 1400 1400 1400
POSSIBle APPlICATIONS
Door leaf installation, hinge side
Transom installation, hinge side3 ●4 ●4
Opening angle (max.) hinge side5 180° 180° 180° 180° 180° 180° 180° 5 180° 5 180° 180°
Door leaf installation, opposite hinge side
Transom installation, opposite hinge side3
FUNCTIONS
Closing force, adjustable
Back check, adjustable ●6 ●7 ●7
Hydraulic latching action, adjustable
Delayed closing, adjustable ●8 ●8
Closing speed, adjustable
Latching action speed, adjustable
Opening assistance integrated
Opening assistance can be switched off
Flexible opening restrictor
Mechanical hold-open device9
Electric hold-open device
Electric hold-open device for free swing or hold-open magnet
Smoke switch control unit integrated
Mechanical closing sequence control, integrated
For double leaf doors
TS 5000 ISM ECline1 TS 5000 L-ISM ECline1 TS 5000 ISM1 TS 5000 L-ISM1 TS 5000 L-ISM- VPK1 TS 5000 E-ISM1 TS 5000 L-E-ISM1 TS 5000 L-E-ISM- VPK1 TS 5000 R-ISM1 TS 5000 L-R-ISM1 TS 5000 L-R-ISM- VP1
Approvalforfireandsmokeprotectiondoors2
Barrier-free in accordance with DIN 18040 up to leaf width (max.) in mm EN5 1250 EN5 1250 EN4/ 1100 EN5/ 12503 EN4/ 1100 EN5/ 12503 EN4 1100 FSA4 (FSA FL) FSA4 FSA4 FSA4 (FSA FL) FSA4 FSA4
Closing force acc. to EN 1154 3-5 3-5 2-6 2-6 2-6 2-6 2-6 2-6 2-6 2-6 3-6
Door leaf width (max.) in mm 1250 1250 1400 1400 1400 1400 1400 1400 1400 1400 1400
POSSIBle APPlICATIONS
Door leaf installation, hinge side
Transom installation, hinge side5)
Opening angle (max.) hinge side6) 180° 6 180° 6 6 180° 6 6 180° 6 6
Door leaf installation, opposite hinge side
Transom installation, opposite hinge side5)
FUNCTIONS
Closing force, adjustable
Back check, adjustable
Hydraulic latching action, adjustable
Delayed closing, adjustable ●7 ●7
Closing speed, adjustable
Latching action speed, adjustable
Opening assistance integrated ○8 ○8
Opening assistance can be switched off
Flexible opening restrictor
Mechanical hold-open device10)
Electric hold-open device
Electric hold-open device for free swing or hold-open magnet
Smoke switch control unit integrated
Mechanical closing sequence control, integrated

For single leaf doors
● = yes | ○ = optional
1 Valid for Germany. Regulations may differ for other countries and must therefore be determined from local provisions. In such cases, contact your local
GEZE branch/representative. | 2 FSA = hold-open system; FSA FL = hold-open system with free swing | 3 For fire protection doors with corresponding
proof of suitability | 4 Special model | 5 Opening angle (max.) opposite hinge side see chapter: General product functions and information | 6 Model
TS 3000 V BC | 7 Back check in transom installation, opposite hinge side not effective | 8 Model TS 5000 S / TS 5000 S ECline | 9 Can be retrofitted,
not to fire and smoke protection doors
For double leaf doors
● = yes | ○ = optional
1 System solution consisting of 2 TS 5000 (L) overhead door closers and appropriate ISM , E-ISM or R-ISM guide rail for installation on the hinge or opposite hinge side (BG version) | 2 Valid for Germany. Regulations may differ for other countries and must therefore be determined from local provisions. In such cases, contact your local GEZE branch/representative. | 3 Closing force up to EN4 /1100 mm with standard and up to EN5/1250 mm with ECline closer | 4 FSA = hold-open system; FSA FL = hold-open system with free swing | 5 For fire protection doors with corresponding proof of suitability | 6 Opening angle (max.) on opposite hinge side, see chapter: General product functions and information | 7 Model TS 5000 S / TS 5000 S ECline | 8 Available for the active leaf | 9 Only available to a limited extent | 10 Can be retrofitted, not to fire and smoke protection doors

FOR SINGLE LEAF DOORS

  • TS 1500 G
  • TS 3000 V
  • TS 5000 ECline
  • TS 5000
  • TS 5000 E
  • TS 5000 R

FOR SINGLE LEAF DOORS WITH FREE SWING FUNCTION

  • TS 5000 EFS
  • TS 5000 RFS

FOR DOUBLE LEAF DOORS

  • TS 5000 ISM ECline
  • TS 5000 ISM
  • TS 5000 E-ISM
  • TS 5000 R-ISM

FOR DOUBLE LEAF DOORS WITH FREE SWING FUNCTION

  • TS 5000 ISM / E-ISM / R-ISM 11
Fire Doors
Download
Activation Devices - GEZEGC304
Download
Activation Devices - GEZE Activation Detectors
Download
Activation Devices - GEZEGC302 radar Movement Detector
Download
Activation Devices - GEZEGC306 Proximity Switch
Download
Activation Devices - GEZELED Sensor Buttons
Download
Disability System
Download
Space-saving, elegant and modern design
Space-saving, elegant and modern design
Smoke-proof swing doors for increased safety through smoke protection
Smoke-proof swing doors for increased safety through smoke protection
High-powered series capable of safely moving heavy doors
High-powered series capable of safely moving heavy doors

Suitable for a Wide Range of Industies

Health

Custom designed solutions for clean spaces

Government

Solutions to maximise accessibility and safety

Office

Elegant solutions for integrated building management performance

Retail

Customised designs for superior aesthetics and high traffic use

Education

Full control systems for occupant safety and wellbeing

Building & Construction

Deliver premium comfort, reliability and security with custom solutions

Frequently Asked Questions

Yes! We offer full scoping, design, fabrication and installation of custom automatic sliding doors.

Yes, the automation and door drive technology is fully integrated with your building management system to offer you complete control.

Your servicing schedule will depend on the hardware, environment and traffic frequency. We create a custom servicing schedule for each solution and our remote monitoring technology provides instant alerts for servicing and maintenance, so you don’t need to do any extra administration.

Yes, we provide full service solutions so you don’t have to worry about unexpected or additional costs. Our end-to-end service is specifically designed to deliver the best in the market product and service in a convenient and cost efficient solution.

Enquire about a custom solution for your project.